Logo
Gosund 13A Power Monitoring Plug
UK
Model reference: UP111
Gosund 13A

Available from:







Flashed with:
Tuya-Convert

GPIO #Component
GPIO00 None
GPIO01 Led1i
GPIO02 None
GPIO03 Button1
GPIO04 BL0937 CF
GPIO05 HLWBL CF1
GPIO09 None
GPIO10 None
GPIO12 HLWBL SELi
GPIO13 LedLinki
GPIO14 Relay1
GPIO15 None
GPIO16 None
ADC0 None
Template for Tasmota v9.1+
{"NAME":"Gosund UP111","GPIO":[0,320,0,32,2720,2656,0,0,2624,576,224,0,0,0],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.

Tuya-Convert might not be possible for this device if the manufacturer started using newest Tuya firmware since this template was published (2020-01-12).

Update: box of 4 bought from amazon.uk on 14-Jan-2021 and flashed successfully with tuya-convert.