16A Power Monitoring Plug (AWP16L)
Available from:
Amazon.de
Install method:
USB to Serial
| GPIO # | Component |
|---|---|
| GPIO00 | None |
| GPIO01 | None |
| GPIO02 | Led_i 1 |
| GPIO03 | None |
| GPIO04 | None |
| GPIO05 | BL0937 CF |
| GPIO09 | None |
| GPIO10 | None |
| GPIO12 | HLWBL SELi |
| GPIO13 | Button 1 |
| GPIO14 | HLWBL CF1 |
| GPIO15 | Relay 1 |
| GPIO16 | None |
| GPIO17 | None |
Configuration
{"NAME":"AWP16L","GPIO":[0,0,320,0,0,2720,0,0,2624,32,2656,224,0,0],"FLAG":0,"BASE":45}
Configuration (old format, will be converted to new template when applied)
{"NAME":"AWP16L","GPIO":[0,0,56,0,0,134,0,0,131,17,132,21,0],"FLAG":0,"BASE":45}
This device now comes with a Wi-Fi module incompatible with Tasmota
For more accurate energy consumption measurements this device requires power monitoring calibration.- Disassembly is easy. No glue, just one screw and three clips.
- The ESP Module is ESP8266-S3. Pinout for flashing is described here: https://sylvainzimmer.com/blog/2021/09/smart-plugs-tasmota/