Arlec Smart Power Monitoring Plug (PC399HA)
Available from:
Bunnings.com.au
Bunnings.co.nz
Install method:
USB to Serial
GPIO # | Component |
---|---|
GPIO00 | None |
GPIO01 | None |
GPIO02 | None |
GPIO03 | Button1 |
GPIO04 | BL0937 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | Led1i |
GPIO14 | Relay1 |
GPIO15 | None |
GPIO16 | None |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"PC399HA","GPIO":[0,0,0,17,134,132,0,0,131,56,21,0,0],"FLAG":0,"BASE":52}
For more accurate energy consumption measurements this device requires power monitoring calibration.
Device is running 1.1.4 of Tuya FW, so not yet working with tuya-convert (11/04/2020).
To flash via UART, SMD capacitor C4B must be removed (below button), due to its effect on the rise times on the RXD. Be careful not to damage LED when removing this Capacitor.
A video showing the disassembly and flashing process: https://youtu.be/MAb5f0rxvKU