Logo
Athom 16A Power Monitoring Plug
EU
Model reference: PG01EU16A
Athom 16A

Available from:
Aliexpress.com
Tindie.com



Manufacturer:
Athom.tech

Flashed with:
Tasmota pre-flashed

GPIO #Component
GPIO00 None
GPIO01 None
GPIO02 None
GPIO03 Button1
GPIO04 BL0937 CF
GPIO05 HLWBL CF1
GPIO09 None
GPIO10 None
GPIO12 HLWBL SELi
GPIO13 LedLink
GPIO14 Relay1
GPIO15 None
GPIO16 None
FLAG None

Template

{"NAME":"Athom PG01EU16A","GPIO":[0,0,0,17,134,132,0,0,131,157,21,0,0],"FLAG":0,"BASE":1}

This device comes with Tasmota pre-flashed straight from the factory!

For more accurate energy consumption measurements this device requires power monitoring calibration.

Athom devices come with modified Tasmota which is not entirely compatible with regular releases. To have full compatibility upgrade to main release version.

Before upgrading set your device to module Generic (19) (yes, it is 19 in Athom's build) to avoid clicking relays, flashing lights or button resets after upgrade. Perform upgrade to release version using file upload method with tasmota.bin.gz or tasmota-lite.bin.gz or with OTAUrl. DO NOT use tasmota-minimal.bin!.

None of the settings will be retained after the upgrade. You will have to search for Tasmota AP and redo the Wi-Fi and MQTT configuration. Once you've upgraded do Reset 6 to erase flash and apply the template!

If you use OTAUrl upgrade with precompiled binaries there is a chance of soft bricking your device. In most cases it is possible to restore it using Power Cycle Recovery or, if that fails, with serial flash.

How to open the plug

PCB