Logo
Athom 16A Switzerland v2 Power Monitoring Plug (PG05V2-CH16A-TAS)
CH
Athom 16A Switzerland v2

Available from:
Aliexpress.com





Manufacturer:
Athom.tech

Install method:
Tasmota pre-installed

GPIO #Component
GPIO00 None
GPIO01 None
GPIO02 None
GPIO03 CSE7766 Rx
GPIO04 None
GPIO05 Button 1
GPIO09 None
GPIO10 None
GPIO12 Relay 1
GPIO13 LedLinki
GPIO14 None
GPIO15 None
GPIO16 None
GPIO17 None
Configuration
{"NAME":"Athom Plug V2","GPIO":[0,0,0,3104,0,32,0,0,224,576,0,0,0,0],"FLAG":0,"BASE":18}
This device comes with Tasmota already installed!

For more accurate energy consumption measurements this device requires power monitoring calibration.

HLW8032 occasionally report invalid power measurements for load values below 5W. During this situation it sometimes reports a valid load. By setting SetOption39 to 128 (default) it must read at least 128 invalid power readings before reporting there is no load.

To discard all loads below 6W simply set SetOption39 1 (0 will reset to default on next restart) so it will report no load below 6W.