Logo
Athom 16A AU V3 Plug (PG05V3-AU10A-TAS-1)
AU
Athom 16A AU V3

Available from:
Aliexpress.com





Manufacturer:
Athom.tech

Install method:
Tasmota pre-installed

GPIO #Component
GPIO00 None
GPIO01 None
GPIO02 None
GPIO03 Button 1
GPIO04 None
GPIO05 Relay 1
GPIO06 LedLinki
GPIO07 None
GPIO08 None
GPIO09 None
GPIO10 None
GPIO12 None
GPIO13 None
GPIO18 None
GPIO19 None
GPIO20 CSE7766 Rx
GPIO21 None
Configuration for ESP32-C3
{"NAME":"Athom Plug V3","GPIO":[0,0,0,32,0,224,576,0,0,0,0,0,0,0,0,0,0,0,0,0,3104,0],"FLAG":0,"BASE":1}
This device comes with Tasmota already installed!

For more accurate energy consumption measurements this device requires power monitoring calibration.

HLW8032 occasionally report invalid power measurements for load values below 5W. During this situation it sometimes reports a valid load. By setting SetOption39 to 128 (default) it must read at least 128 invalid power readings before reporting there is no load.

To discard all loads below 6W simply set SetOption39 1 (0 will reset to default on next restart) so it will report no load below 6W.