Connex Power Monitoring Plug (CC-P1000)
Available from:
Makro.co.za
Manufacturer:
Connexconnect.com
Install method:
Tuya-Convert
GPIO # | Component |
---|---|
GPIO00 | Button1 |
GPIO01 | None |
GPIO02 | None |
GPIO03 | None |
GPIO04 | HLW8012 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | Led1i |
GPIO14 | Relay1 |
GPIO15 | None |
GPIO16 | None |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"Connex Smart T","GPIO":[17,0,0,0,133,132,0,0,131,56,21,0,0],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2019-12-16).
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2019-12-16).