Logo
Dilisens NX-SP201 Mini 2 in 1 Power Monitoring Plug
US
Model reference: NX-SP201
Dilisens NX-SP201 Mini 2 in 1

Available from:
Amazon.com






Flashed with:
Tuya-Convert

GPIO #Component
GPIO00 None
GPIO01 None
GPIO02 HLWBL SELi
GPIO03 None
GPIO04 BL0937 CF
GPIO05 HLWBL CF1
GPIO09 Led1
GPIO10 Relay1
GPIO12 Button2
GPIO13 Relay2
GPIO14 Button1
GPIO15 None
GPIO16 None
FLAG None

Template

{"NAME":"NX-SP201","GPIO":[0,0,131,0,134,132,52,21,18,22,17,0,0],"FLAG":0,"BASE":18}

Tuya-Convert might not be possible for this device if the manufacturer started using newest Tuya firmware since this template was published (2020-02-21).

For more accurate energy consumption measurements this device requires power monitoring calibration.

Hold the left switch/button to enter pairing mode