GPIO #Component
GPIO00 None
GPIO01 Led1i
GPIO02 None
GPIO03 Button1
GPIO04 BL0937 CF
GPIO05 HLWBL CF1
GPIO09 None
GPIO10 None
GPIO12 HLWBL SELi
GPIO13 Led2i
GPIO14 Relay1
GPIO15 None
GPIO16 None
FLAG None

Template

{"NAME":"Gosund SP1 v23","GPIO":[0,56,0,17,134,132,0,0,131,57,21,0,0],"FLAG":0,"BASE":55}

For more accurate energy consumption measurements this device requires power monitoring calibration.

There are three clones – use the device type Teckin:

  • Gosund SP1 (Version 2.3)
    • To configure select Gosund SP1 v23 (55) or console command Module 55
  • Gosund SP1 (Version 2.4)
    • To configure select Gosund SP1 v23 (55) or console command Module 55
  • BlitzWolf SHP2 (Version 2.3)

For more pictures see: https://www.bastelbunker.de/gosund-sp1-mit-tasmota/

For power monitoring calibration see wiki