Gosund 2 in 1 Power Monitoring Plug (WP2)
Available from:
Amazon.com
Manufacturer:
Gosund.com
Install method:
Tuya-Convert
GPIO # | Component |
---|---|
GPIO00 | Led2i |
GPIO01 | Led1 |
GPIO02 | LedLink |
GPIO03 | None |
GPIO04 | Relay1 |
GPIO05 | BL0937 CF |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | Button1 |
GPIO14 | HLWBL CF1 |
GPIO15 | Relay2 |
GPIO16 | Button2 |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"Gosund WP212","GPIO":[57,52,157,0,21,134,0,0,131,17,132,22,18],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2020-09-05).
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2020-09-05).
This template supports energy monitoring; however, not all revisions of the WP2 support energy monitoring. Try the templates for WP211 and WP212 if your plug doesn’t support energy monitoring.