Koolertron Power Monitoring Outdoor Plug (C168)
Available from:
Amazon.com
Install method:
Tuya-Convert
GPIO # | Component |
---|---|
GPIO00 | None |
GPIO01 | Button1 |
GPIO02 | None |
GPIO03 | Led1i |
GPIO04 | BL0937 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | Relay1 |
GPIO13 | HLWBL SELi |
GPIO14 | Relay2 |
GPIO15 | Relay3 |
GPIO16 | None |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"C168 Outdoor","GPIO":[0,17,0,56,134,132,0,0,21,131,22,23,0],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2020-07-26).
WARNING: New Tuya devices have replaced their Wi-Fi module with one incompatible with Tasmota!!!
Tuya-Convert might not be possible for this device since the template was added (2020-07-26).