Nedis P120 Power Monitoring Plug (WIFIP120EWT)
Available from:
Amazon.de
Manufacturer:
Nedis.fr
Install method:
USB to Serial
GPIO # | Component |
---|---|
GPIO00 | Button1 |
GPIO01 | None |
GPIO02 | None |
GPIO03 | None |
GPIO04 | HLW8012 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | Led1i |
GPIO14 | Relay1 |
GPIO15 | None |
GPIO16 | None |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"WIFIP120EWT","GPIO":[17,0,0,0,133,132,0,0,131,56,21,0,0],"FLAG":0,"BASE":49}
For more accurate energy consumption measurements this device requires power monitoring calibration.
Requires removal of 6 screws to reach module and solder wires for flashing
Connect pin I00 to ground at start-up to enable flashing
Pin I00 can remain connected during flashing
It is necessary to reboot after each use of esptool