Logo
Nedis P120 Power Monitoring Plug (WIFIP120EWT)
FR
Nedis P120

Available from:
Amazon.de





Manufacturer:
Nedis.fr

Install method:
USB to Serial

GPIO #Component
GPIO00 Button1
GPIO01 None
GPIO02 None
GPIO03 None
GPIO04 HLW8012 CF
GPIO05 HLWBL CF1
GPIO09 None
GPIO10 None
GPIO12 HLWBL SELi
GPIO13 Led1i
GPIO14 Relay1
GPIO15 None
GPIO16 None
FLAG None
Configuration (old format, will be converted to new template when applied)
{"NAME":"WIFIP120EWT","GPIO":[17,0,0,0,133,132,0,0,131,56,21,0,0],"FLAG":0,"BASE":49}
For more accurate energy consumption measurements this device requires power monitoring calibration.

Requires removal of 6 screws to reach module and solder wires for flashing

Connect pin I00 to ground at start-up to enable flashing

Pin I00 can remain connected during flashing

It is necessary to reboot after each use of esptool