| GPIO # | Component |
|---|---|
| GPIO00 | None |
| GPIO01 | None |
| GPIO02 | None |
| GPIO03 | None |
| GPIO04 | Led1i |
| GPIO05 | BL0937 CF |
| GPIO09 | None |
| GPIO10 | None |
| GPIO12 | HLWBL SELi |
| GPIO13 | Button1 |
| GPIO14 | HLWBL CF1 |
| GPIO15 | Relay1 |
| GPIO16 | None |
| FLAG | Analog |
Configuration (old format, will be converted to new template when applied)
{"NAME":"NX-SM200","GPIO":[0,0,0,0,56,134,0,0,131,17,132,21,0],"FLAG":1,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
If the first template doesn’t work try this alternative:
{"NAME":"NX-SM200","GPIO":[0,56,0,17,134,132,0,0,131,30,21,0,0],"FLAG":0,"BASE":55}
The other template for this plug didn’t work for me. This one is based on the Gosound SP1 v23 (55) template, I added the blue LED as relay2