Panamalar NX-SM200 Power Monitoring Plug
Available from:
Amazon.de
GPIO # | Component |
---|---|
GPIO00 | None |
GPIO01 | None |
GPIO02 | None |
GPIO03 | None |
GPIO04 | Led1i |
GPIO05 | BL0937 CF |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | Button1 |
GPIO14 | HLWBL CF1 |
GPIO15 | Relay1 |
GPIO16 | None |
FLAG | Analog |
Configuration (old format, will be converted to new template when applied)
{"NAME":"NX-SM200","GPIO":[0,0,0,0,56,134,0,0,131,17,132,21,0],"FLAG":1,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
If the first template doesn’t work try this alternative:
{"NAME":"NX-SM200","GPIO":[0,56,0,17,134,132,0,0,131,30,21,0,0],"FLAG":0,"BASE":55}
The other template for this plug didn’t work for me. This one is based on the Gosound SP1 v23 (55) template, I added the blue LED as relay2