Logo
Shelly Plus i4 Switch Module (SNSN-0024X)
Shelly Plus i4
GPIO #Component
GPIO00 None
GPIO01 None
GPIO02 None
GPIO03 None
GPIO04 None
GPIO05 None
GPIO09 None
GPIO10 None
GPIO12 Switch_n 1
GPIO13 None
GPIO14 Switch_n 2
GPIO15 None
GPIO16 None
GPIO17 None
GPIO18 None
GPIO19 None
GPIO20 None
GPIO21 None
GPIO22 None
GPIO23 None
GPIO24 None
GPIO25 None
GPIO26 Switch_n 4
GPIO27 Switch_n 3
GPIO6 None
GPIO7 None
GPIO8 None
GPIO11 None
GPIO32 None
GPIO33 None
GPIO34 None
GPIO35 None
GPIO36 None
GPIO37 None
GPIO38 None
GPIO39 None
Configuration for ESP32
{"NAME":"Shelly Plus i4","GPIO":[0,0,0,0,0,0,0,0,192,0,193,0,0,0,0,0,0,0,0,0,0,0,195,194,0,0,0,0,0,0,0,0,0,0,0,0],"FLAG":0,"BASE":1,"CMND":"SwitchMode1 1 | SwitchMode2 1 | SwitchMode3 1 | SwitchMode4 1 | SwitchTopic 0 | SetOption114 1"}
Flash only with ESP32-SOLO1 tasmota32solo1... binaries.

WARNING!!! Devices with firmaware v1.10+ cannot be flashed OTA anymore

Use code BLAKADDER23 when buying from mediarath.de Tasmota category and a minimum order value of 50€ for a 10% discount. The code is valid until end of 2023.

Example to publish switch events to separate topics

Backlog Rule1 on Switch1#state do Publish stat/%topic%/SWITCH1 %value% endon on Switch2#state do Publish stat/%topic%/SWITCH2 %value% endon on Switch3#state do Publish stat/%topic%/SWITCH3 %value% endon on Switch4#state do Publish stat/%topic%/SWITCH4 %value% endon; Rule1 1