Slitinto NX-SM200 Power Monitoring Plug
GPIO # | Component |
---|---|
GPIO00 | None |
GPIO01 | None |
GPIO02 | None |
GPIO03 | Button1 |
GPIO04 | BL0937 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | None |
GPIO13 | Led1 |
GPIO14 | Relay1 |
GPIO15 | HLWBL SEL |
GPIO16 | None |
FLAG | None |
Configuration (old format, will be converted to new template when applied)
{"NAME":"NX-SM200","GPIO":[0,0,0,17,134,132,0,0,0,52,21,130,0],"FLAG":0,"BASE":45}
For more accurate energy consumption measurements this device requires power monitoring calibration.
Alternative template for .fr seller:
{"NAME":"NX-SM200","GPIO":[17,0,0,0,133,132,0,0,131,158,21,0,0],"FLAG":0,"BASE":18}
Another EU template (recognised by the status LEDs leaking light around the button):
{"NAME":"NX-SM200","GPIO":[576,0,0,2624,0,2720,0,0,0,32,2656,224,0,0],"FLAG":0,"BASE":18}
If the original template works but after calibration the power factor is too low and current too high (and power never exceeds the one it was calibrated with), then try using:
{"NAME":"NX-SM200","GPIO":[0,0,0,32,2688,2656,0,0,2624,576,224,0,0,0],"FLAG":0,"BASE":18}
It’s basically the french one but button pin is from the original one.