SmartGrade Power Monitoring Switch (AC 5005)
Available from:
Smartgrade.co.il
Manufacturer:
Smartgrade.co.il
Install method:
USB to Serial
GPIO # | Component |
---|---|
GPIO00 | None |
GPIO01 | None |
GPIO02 | None |
GPIO03 | Button 1 |
GPIO04 | HLW8012 CF |
GPIO05 | HLWBL CF1 |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | LedLink |
GPIO14 | Relay 1 |
GPIO15 | None |
GPIO16 | None |
GPIO17 | None |
Configuration
{"NAME":"SmartGrade AC 5005","GPIO":[0,0,0,32,2688,2656,0,0,2624,544,224,0,0,0],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requires power monitoring calibration.
No ready pins for serial, had to solder directly to the chip for the initial flash.